SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Mounting Type Features Base Product Number Approval Agency Termination Ingress Protection DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Filter Type Connector Type Material Flammability Rating Number of Positions Panel Cutout Dimensions Connector Style Panel Thickness Current Rating - Appliance Inlet Voltage Rating - Appliance Inlet Current Rating - Filter Switch Features Current Rating - Circuit Breaker Accomodates a Fuse Fuse Holder, Drawer
7-6609930-9 TE Connectivity Corcom Filters 7-6609930-9 25.0994
RFQ
ECAD 1183 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange - 6609930 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PE000DSX0 EAR99 8536.69.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
1-6609987-3 TE Connectivity Corcom Filters 1-6609987-3 3.8178
RFQ
ECAD 3451 0.00000000 TE Connectivity Corcom Filters SRB, Corcom Bulk Active Panel Mount, Flange Front or Rear Side Mount, Shielded 6609987 CSA, UL, VDE Wire Leads - download ROHS3 Compliant Not Applicable Vendor Undefined EAR99 8536.30.8000 40 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Variable Size IEC 320-C14 - 15A 120/250VAC 15A - - No -
7-6609943-2 TE Connectivity Corcom Filters 7-6609943-2 25.9338
RFQ
ECAD 4684 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In - 6609943 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSCS0DS30 EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 3A 120VAC 3A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
1-6609006-6 TE Connectivity Corcom Filters 1-6609006-6 12.8900
RFQ
ECAD 31 0.00000000 TE Connectivity Corcom Filters EJS, Corcom Bulk Active Panel Mount, Snap-In - 6609006 CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Affected EAR99 8548.00.0000 40 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Rectangular - 30.48mm x 22.86mm IEC 320-C14 0.031" ~ 0.068" (0.79mm ~ 1.73mm) 10A 120/250VAC 10A - - No -
3-6609949-9 TE Connectivity Corcom Filters 3-6609949-9 26.2444
RFQ
ECAD 5615 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In - 6609949 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSLS0DS30 EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 3A 120VAC 3A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
20SRB1-Y TE Connectivity Corcom Filters 20SRB1-Y 7.3700
RFQ
ECAD 39 0.00000000 TE Connectivity Corcom Filters SRB, Corcom Tray Active Panel Mount, Flange Front or Rear Side Mount 20S CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8536.69.4030 24 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Variable Size IEC 320-C20 - 20A 120/250VAC 20A - - No -
5-6609940-9 TE Connectivity Corcom Filters 5-6609940-9 28.7150
RFQ
ECAD 1017 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Conversion Clip, Shielded, Voltage Selector 6609940 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 12 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 28.45mm x 54.10mm IEC 320-C14 - 3A 120VAC 3A Switch On-Off - Yes (Fuse Not Included) Fuse Holder
6609014-2 TE Connectivity Corcom Filters 6609014-2 -
RFQ
ECAD 9997 0.00000000 TE Connectivity Corcom Filters EF, Corcom Bulk Obsolete Panel Mount, Flange; Through Hole, Right Angle - 6609014 CSA, SEV, UL, VDE Solder Eyelet - download Not Applicable REACH Unaffected EAR99 8536.30.8000 40 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Rectangular - 30.48mm x 22.86mm IEC 320-C14 - 1A 120/250VAC 1A - - No -
3-6609929-7 TE Connectivity Corcom Filters 3-6609929-7 27.4821
RFQ
ECAD 5841 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Conversion Clip, Shielded, Voltage Selector 6609929 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 6A 120VAC 6A Switch On-Off - Yes (Fuse Not Included) Fuse Holder
6-6609942-5 TE Connectivity Corcom Filters 6-6609942-5 29.6806
RFQ
ECAD 6073 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In Shielded, Voltage Selector 6609942 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSCSSDH6A EAR99 8536.69.8000 16 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 Rectangular - 28.45mm x 64.01mm IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 6A 120VAC 6A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
12HPENS1-NG TE Connectivity Corcom Filters 12HPENS1-NG 47.1700
RFQ
ECAD 14 0.00000000 TE Connectivity Corcom Filters HP, Corcom Box Active Panel Mount, Flange - cURus, ENEC, UL Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4030 9 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Rectangular - 31.50mm x 56.60mm IEC 320-C18 0.039" ~ 0.079" (1.00mm ~ 2.00mm) - No Fuse Holder
1-6609945-4 TE Connectivity Corcom Filters 1-6609945-4 22.7925
RFQ
ECAD 2190 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In - 6609945 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSC00DS30 EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 3A 120/250VAC 3A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
PS00XD000 TE Connectivity Corcom Filters PS00XD000 17.6700
RFQ
ECAD 1 0.00000000 TE Connectivity Corcom Filters P, Chameleon, Corcom Bulk Active Panel Mount, Snap-In Voltage Selector PS00 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant 1 (Unlimited) Vendor Undefined EAR99 8536.69.8000 16 Unfiltered - Commercial Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.083" (0.79mm ~ 2.11mm) 10A 120VAC - - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
1-1609112-5 TE Connectivity Corcom Filters 1-1609112-5 13.6700
RFQ
ECAD 1 0.00000000 TE Connectivity Corcom Filters CU, Corcom Bulk Last Time Buy Panel Mount, Snap-In - 1609112 CSA, UL, VDE Quick Connect - 0.189" (4.8mm) - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8537.10.9170 42 Unfiltered - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 26.70mm x 31.60mm IEC 320-C14 0.025" ~ 0.083" (0.63mm ~ 2.10mm) 15A 120/250VAC - Switch On-Off - No -
6-6609959-6 TE Connectivity Corcom Filters 6-6609959-6 22.5000
RFQ
ECAD 69 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Interconnection Block 6609959 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8537.10.9170 12 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 26.92mm x 54.10mm IEC 320-C14 - 10A 120VAC 10A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse