Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Base Product Number | Current - Supply | Ingress Protection | Output Type | Voltage - Supply | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Output Configuration | Sensing Method | Cable Length | Adjustment Type | Sensing Distance | Response Time | Light Source | Connection Method | Voltage - Output Difference (Typ) @ Distance | Voltage - Output (Typ) @ Distance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
T18SP6DQ | - | ![]() |
6268 | 0.00000000 | Banner Engineering Corporation | T18 | Box | Obsolete | -40°C ~ 70°C | T18SP6 | NEMA 6P, IP69K | 10V ~ 30V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8541.49.8000 | 1 | PNP - Dark-ON/Light-ON | Diffuse | - | Adjustable, Potentiometer | 19.685" (500mm) | 3ms | Infrared (880nm) | Connector | ||||||
![]() |
T18SN6DQ | - | ![]() |
2581 | 0.00000000 | Banner Engineering Corporation | T18 | Box | Obsolete | -40°C ~ 70°C | T18SN6 | NEMA 6P, IEC IP67, IEC IP69K | 10V ~ 30V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 2170-T18SN6DQ | EAR99 | 8541.49.8000 | 1 | NPN - Dark-ON/Light-ON | Diffuse | - | Adjustable, Potentiometer | 19.685" (500mm) | 3ms | Infrared (880nm) | Connector | |||||
![]() |
QS18VP6LPQ8 | 90.0000 | ![]() |
92 | 0.00000000 | Banner Engineering Corporation | QS18 | Box | Active | -20°C ~ 70°C | QS18VP6 | NEMA 6P, IEC IP67 | 10V ~ 30V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 2170-QS18VP6LPQ8 | EAR99 | 8541.49.8000 | 1 | PNP - Dark-ON/Light-ON | Retroreflective, Polarized | - | Adjustable, Potentiometer | 137.795" (3.5m) | 600µs | Red LED | Connector | |||||
![]() |
QS18AB6AF300 | 116.0000 | ![]() |
2 | 0.00000000 | Banner Engineering Corporation | QS18 | Box | Active | -20°C ~ 55°C | QS18A | NEMA 6P, IEC IP67 | 10V ~ 30V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 2170-QS18AB6AF300 | EAR99 | 8541.49.8000 | 1 | NPN/PNP - Light-ON | Background Suppression | 78.74" (2m) | Adjustable | 11.811" (300mm) | 2.5ms | Red LED | Cable | |||||
![]() |
T186EQ | - | ![]() |
4112 | 0.00000000 | Banner Engineering Corporation | T18 | Box | Obsolete | -40°C ~ 70°C | T186E | NEMA 6P, IEC IP69K | 10V ~ 30V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 2170-T186EQ | EAR99 | 8541.49.8000 | 1 | - | Through-Beam | - | - | 787.402" (20m) | - | Infrared (950nm) | Connector | |||||
![]() |
SL30VB6V | 149.0000 | ![]() |
2 | 0.00000000 | Banner Engineering Corporation | SL30 | Box | Active | -40°C ~ 70°C | SL30VB6 | NEMA 6P, IP67 | 10V ~ 30V | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8541.49.8000 | 1 | NPN/PNP - Dark-ON/Light-ON | Through-Beam | 78.74" (2m) | Adjustable, Potentiometer | 1.181" (30mm) | 1ms | Red (680nm) | Cable | ||||||
![]() |
T18RW3FF100 | 170.0000 | ![]() |
1 | 0.00000000 | Banner Engineering Corporation | T18 | Box | Active | -40°C ~ 70°C | T18RW3 | NEMA 6P, IEC IP67, IEC IP69K | 20 ~ 250 VAC | - | 1 (Unlimited) | REACH Unaffected | 2170-T18RW3FF100 | 1 | Dark-On | Background Suppression | 78.74" (2m) | - | 3.937" (100mm) | 16ms | Infrared (880nm) | Cable | ||||||||
![]() |
Q45BB6FV | 142.0000 | ![]() |
1 | 0.00000000 | Banner Engineering Corporation | Q45 | Box | Active | -40°C ~ 70°C | Q45B | NEMA 6P, IEC IP67 | 10V ~ 30V | - | 1 (Unlimited) | REACH Unaffected | EAR99 | 8541.49.8000 | 1 | NPN/PNP - Dark-ON/Light-ON - Selectable | Fiber Optic | 78.74" (2m) | Adjustable, Potentiometer | - | 2ms | Red (650nm) | Cable | |||||||
![]() |
VS2AP5CV30 | 111.0000 | ![]() |
2 | 0.00000000 | Banner Engineering Corporation | VS2 | Box | Active | -20°C ~ 55°C | VS2AP5 | NEMA 6P, IEC IP67 | 10V ~ 30V | download | 1 (Unlimited) | REACH Unaffected | EAR99 | 8541.49.8000 | 1 | PNP - Light-ON | Convergent | 78.74" (2m) | - | 1.181" (30mm) | 1ms | Red (660nm) | Cable | |||||||
![]() |
QS30EXSH2OQ5 | 203.0000 | ![]() |
3 | 0.00000000 | Banner Engineering Corporation | QS30 | Box | Active | -20°C ~ 60°C | QS30E | NEMA 6P, IEC IP67 | 10V ~ 30V | - | 1 (Unlimited) | REACH Unaffected | EAR99 | 8541.49.8000 | 1 | - | Through-Beam | - | - | 26.25' (8m) | 10ms | LED | Connector | |||||||
![]() |
PVL225NQ | 348.0000 | ![]() |
2 | 0.00000000 | Banner Engineering Corporation | PVL | Box | Active | 0°C ~ 50°C | PVL225 | IEC IP50 | 12V ~ 30V | download | 1 (Unlimited) | REACH Unaffected | 1 | NPN | Retroreflective, NonPolarized | 78.74" (2m) | - | 4.9' (1.50m) | 2ms | LED | Cable with Connector | |||||||||
![]() |
S18SN6D W/30 | 90.0000 | ![]() |
2 | 0.00000000 | Banner Engineering Corporation | S18 | Box | Active | -40°C ~ 70°C | S18SN6 | NEMA 6P, IEC IP67, IEC IP69K | 10V ~ 30V | - | 1 (Unlimited) | REACH Unaffected | 1 | NPN - Dark-ON/Light-ON - Selectable | Diffuse | 354.33" (9m) | - | 3.937" (100mm) | 3ms | Infrared (880nm) | Cable | |||||||||
![]() |
S18-2VPFF75-Q8 | 96.0000 | ![]() |
1 | 0.00000000 | Banner Engineering Corporation | S18-2 | Box | Active | -40°C ~ 70°C | S18-2V | NEMA 6P, IEC IP67 | 10V ~ 30V | - | 1 (Unlimited) | REACH Unaffected | 2170-S18-2VPFF75-Q8 | EAR99 | 8541.49.8000 | 1 | PNP - Dark-ON/Light-ON - Selectable | Background Suppression | - | - | 2.953" (75mm) | 1.5ms | Red LED | Connector | ||||||
![]() |
QS18EN6DVQ8 | 90.0000 | ![]() |
2 | 0.00000000 | Banner Engineering Corporation | QS18 | Box | Active | -20°C ~ 70°C | QS18EN6 | NEMA 6P, IEC IP67 | 10V ~ 30V | - | 1 (Unlimited) | REACH Unaffected | 1 | NPN - Dark-ON/Light-ON - Selectable | Diffuse | - | Adjustable | 23.622" (600mm) | 600µs | Red (630nm) | Connector | |||||||||
![]() |
VS8APFF50BQ3 | 216.0000 | ![]() |
1053 | 0.00000000 | Banner Engineering Corporation | VS8 | Box | Active | -20°C ~ 60°C | VS8APFF50 | NEMA 6P, IEC IP67 | 10V ~ 30V | - | 1 (Unlimited) | REACH Unaffected | 1 | PNP - Light-ON | Background Suppression | - | - | 1.969" (50mm) | 500µs | Blue LED | Connector | |||||||||
![]() |
DX80N9Q45LPDIR | 754.0000 | ![]() |
3 | 0.00000000 | Banner Engineering Corporation | Q45 | Box | Obsolete | -40°C ~ 70°C | DX80N | NEMA 6P, IP67 | - | - | 1 (Unlimited) | REACH Unaffected | 2170-DX80N9Q45LPDIR | EAR99 | 8541.49.8000 | 1 | - | Retroreflective | - | - | 5.91" ~ 236.22" (150mm ~ 6000mm) | - | LED | - | ||||||
![]() |
LE250DQP | 1.0000 | ![]() |
6317 | 0.00000000 | Banner Engineering Corporation | LE | Box | Active | -20°C ~ 55°C | LE250 | 70 mA | - | 12V ~ 30V | - | 1 (Unlimited) | REACH Unaffected | 2170-LE250DQP | 1 | 3.94" ~ 15.75" (10 ~ 40cm) | - | - | ||||||||||||
![]() |
PBE43UTMSSMTL12 | 384.0000 | ![]() |
1 | 0.00000000 | Banner Engineering Corporation | PBE4 | Box | Active | 85°C | PBE43 | - | - | - | 1 (Unlimited) | REACH Unaffected | 1 | - | Reflective, Diffuse | - | - | - | - | - | - | |||||||||
![]() |
PBFM16U | 59.0000 | ![]() |
10 | 0.00000000 | Banner Engineering Corporation | PBFM1 | Box | Active | 70°C | PBFM16 | - | - | - | 1 (Unlimited) | REACH Unaffected | 2170-PBFM16U | 1 | - | Reflective, Diffuse | - | - | - | - | - | - | ||||||||
![]() |
PVA300P6EQ | 546.0000 | ![]() |
8 | 0.00000000 | Banner Engineering Corporation | PVA | Box | Active | 0°C ~ 50°C | PVA300 | NEMA 2, IP62 | 12V ~ 30V | download | 1 (Unlimited) | REACH Unaffected | 1 | PNP | Through-Beam | 78.74" (2m) | - | 78.740" (2m) | 52ms | Green LED | Cable with Connector | |||||||||
![]() |
PBCF46U | 84.0000 | ![]() |
4 | 0.00000000 | Banner Engineering Corporation | PBCF4 | Box | Active | 70°C | PBCF46 | - | - | - | 1 (Unlimited) | REACH Unaffected | 2170-PBCF46U | 1 | - | Reflective, Diffuse | - | - | - | - | - | - | ||||||||
![]() |
Q2XRNLAF100-2M | 176.0000 | ![]() |
2 | 0.00000000 | Banner Engineering Corporation | Q2X | Box | Active | -25°C ~ 50°C | IP67 | 10V ~ 30V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8541.49.8000 | 1 | NPN - Dark-ON | Background Suppression | 78.74" (2m) | Adjustable, 3-Turn Potentiometer | 0.709" ~ 3.937" (18mm ~ 100mm) | 850µs | Red (680nm) | Cable | |||||||
![]() |
SMU315D | 209.0000 | ![]() |
8049 | 0.00000000 | Banner Engineering Corporation | MINI-BEAM® | Box | Active | -20°C ~ 55°C | NEMA 1, 2, 3, 3S, 4, 4X, 6, 12, 13, IEC IP67 | 24 ~ 240VAC/DC | - | 1 (Unlimited) | REACH Unaffected | 1 | SPDT - Dark-ON/Light-ON | Diffuse | 78.74" (2m) | Adjustable, Potentiometer | 14.961" (380mm) | 20ms | Infrared LED | Cable | ||||||||||
![]() |
VS8APFF50Q3 | 175.0000 | ![]() |
5044 | 0.00000000 | Banner Engineering Corporation | VS8 | Box | Active | -20°C ~ 60°C | IP67 | 10V ~ 30V | - | 1 (Unlimited) | REACH Unaffected | 1 | PNP - Light-ON | Background Suppression | - | - | 1.969" (50mm) | 500µs | Red (650nm) | Connector | ||||||||||
![]() |
SMU315FV W/30 | 258.0000 | ![]() |
5941 | 0.00000000 | Banner Engineering Corporation | MINI-BEAM® | Box | Active | -20°C ~ 55°C | NEMA 1, 2, 3, 3S, 4, 4X, 6, 12, 13, IEC IP67 | 24 ~ 240VAC/DC | - | 1 (Unlimited) | REACH Unaffected | 1 | SPDT - Dark-ON/Light-ON | Fiber Optic | 354.33" (9m) | Adjustable, Potentiometer | - | - | Red (650nm) | Cable | ||||||||||
![]() |
SMA31EQDP | 119.0000 | ![]() |
1930 | 0.00000000 | Banner Engineering Corporation | MINI-BEAM® | Box | Active | -20°C ~ 70°C | NEMA 1, 2, 3, 3S, 4, 4X, 6, 12, 13, IEC IP67 | 24VAC ~ 240VAC | - | 1 (Unlimited) | REACH Unaffected | 1 | - | Through-Beam | - | Adjustable, Potentiometer | 118.110" (3m) | 1ms, 2ms | Infrared LED | Connector | ||||||||||
![]() |
SMW915LV | 256.0000 | ![]() |
7720 | 0.00000000 | Banner Engineering Corporation | VALU-BEAM | Box | Active | -40°C ~ 50°C | NEMA 1, 2, 3, 3S, 4, 4X, 12, 13, IEC IP66 | 12 ~ 28VAC, 12 ~ 28VDC | - | 1 (Unlimited) | REACH Unaffected | 1 | SPDT - Dark-ON/Light-ON | Retroreflective | 78.74" (2m) | Adjustable | 5.91" ~ 354.33" (150mm ~ 9m) | 20ms | Red (650nm) | Cable | ||||||||||
![]() |
TTR713APSB6D-0.5Q5-CTR | 248.0000 | ![]() |
7582 | 0.00000000 | Banner Engineering Corporation | TTR | Box | Active | -10°C ~ 55°C | IP50 | 18V ~ 30V | - | 1 (Unlimited) | REACH Unaffected | 1 | PNP - Light-ON | Diffuse | - | - | 4.724" (120mm) | 1ms | Infrared (940nm) | Connector | ||||||||||
![]() |
SMU31EQDP | 162.0000 | ![]() |
5463 | 0.00000000 | Banner Engineering Corporation | MINI-BEAM® | Box | Active | -20°C ~ 55°C | NEMA 1, 2, 3, 3S, 4, 4X, 6, 12, 13, IEC IP67 | 24 ~ 240VAC/DC | - | 1 (Unlimited) | REACH Unaffected | 1 | - | Through-Beam | - | Adjustable, Potentiometer | 118.110" (3m) | 20ms | Infrared LED | Connector | ||||||||||
![]() |
T18-2NAES-808380 | 138.0000 | ![]() |
2499 | 0.00000000 | Banner Engineering Corporation | T18-2 | Box | Active | -40°C ~ 70°C | IP67, IP68, IP69K | 10V ~ 30V | - | 1 (Unlimited) | REACH Unaffected | 1 | NPN - Dark-ON/Light-ON - Selectable | Through-Beam | - | Adjustable, Potentiometer | 82.02' (25m) | 1ms, 1.5ms | Red (624nm) | Cable |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse